Need to update your firmware or just download software for your machine? You’ll find it all here. Start by picking your subject below.
You may download and utilize all files on this page for personal use. You may not edit or otherwise modify any material on this page; or redistribute material from this page.
Syntakt OS 1.30 sees an extra four machines added – BD & SD ACOUSTIC, HH LAB, and SY CHIP, as well as some additional parameters for existing machines, and Euclidean sequencer mode. There’s also page loop, sound saving from sequencer trigs, and more. For a full list of changes, see the release notes.
Elektron Transfer is the go to tool for transferring samples, presets, sounds, projects and firmware updates to Analog Rytm MKI/MKII, Analog Four MKI/MKII, Analog Heat MKI/MKII, Analog Keys, Digitakt II, Digitakt, Digitone II, Digitone, Digitone Keys, Model:Samples, Model:Cycles, Syntakt and Analog Heat +FX.
Compatible with:
macOS 10.13 High Sierra and later.
Windows 8 and later.
This information applies to Analog Four, Analog Keys, Analog Four MKII, Analog Heat, Analog Heat MKII, Analog Heat +FX, Analog Rytm, Analog Rytm MKII, Digitakt, Digitakt II, Digitone, Digitone Keys, Digitone II, Syntakt, Model:Cycles, and Model:Samples
To perform a Factory Reset, hold down the [FUNCTION] button ([ACTIVE]/[ON] button for Analog Heat) while powering on the device, then press the appropriate button when the startup menu appears. When the reset has been completed, the unit will reboot.
When you perform a factory reset on Analog Keys or Analog Four or Analog Four MKII, the following happens:
The remaining project slots and sound banks will not be overwritten.
If you wish to keep the active project, remember to save it to a project slot higher than 001 before you perform the factory reset. If you have saved your own sounds to soundbanks A or B, you need to move them to a different bank if you want to keep them.
When you perform a factory reset on Analog Heat MKI or MKII, the following happens:
Preset slots 001–016 will be overwritten with the factory presets. The remaining preset slots will be cleared.
When you perform a factory reset on Analog Heat +FX, the following happens:
Preset slots A001–A019 will be overwritten with the factory presets. The remaining preset slots will be cleared.
When you perform a factory reset on Analog Rytm or Analog Rytm MKII, the following happens:
The remaining project slots and sound banks will not be overwritten.
If you wish to keep the active project, remember to save it to a project slot higher than 001 before you perform the factory reset. If you have saved your own sounds to soundbank A, you need to move them to a different bank if you want to keep them.
When you perform a factory reset on a Digitakt or Digitakt II, the following happens:
The remaining project slots and sound/preset banks will not be overwritten. Any samples that you have transferred to the unit or recorded directly into the unit will remain on the +Drive after a factory reset.
If you wish to keep the active project, remember to save it to a project slot higher than 001 before you perform the factory reset. If you have saved your own sounds/presets to soundbank A, you need to move them to a different bank if you want to keep them.
When you perform a factory reset on Digitone or Digitone Keys or Digitone II, the following happens:
The remaining project slots and sound banks will not be overwritten.
If you wish to keep the active project, remember to save it to a project slot higher than 001 before you perform the factory reset. If you have saved your own sounds to soundbanks A or B, you need to move them to a different bank if you want to keep them.
When you perform a factory reset on Syntakt, the following happens:
The remaining project slots and sound banks will not be overwritten.
If you wish to keep the active project, remember to save it to a project slot higher than 001 before you perform the factory reset. If you have saved your own sounds to soundbanks A through E, you need to move them to a different bank if you want to keep them.
When you perform a factory reset on Model:Cycles or Model:Samples, the following happens:
The remaining project slots and sound banks will not be overwritten.
If you wish to keep the active project, remember to save it to a project slot higher than 01 before you perform the factory reset.
Read moreHere you can find detailed specifications of the power supplies (PSU’s) for the different Elektron devices.
Current Elektron power supply: PSU-4b. These devices were originally shipped with PSU-4 and still work with PSU-4. The PSU-4b power supply includes adapters for the following regions: North America, Continental Europe, the United Kingdom, Brazil, Japan, Korea, Australia, and China. The PSU-4b power supply handles voltages of 100-240 VAC, 50/60Hz.
The power supply you want to use must meet the following specifications:
Voltage: 5 VDC
Minimum Current Rating: 1.2 A
Barrel Connector Size: 3.5 mm outer diameter, 1.35 mm inner diameter
Polarity: Positive center
Current Elektron power supply: PSU-3c. These devices were originally shipped with PSU-3, PSU-3b, or PSU-3c. All these devices work with PSU-3 and PSU-3b (With the exception of Analog Drive which doesn’t work with PSU-3). The PSU-3c power supply handles voltages of 100-240 VAC, 50/60Hz.
The power supply you want to use must meet the following specifications:
Voltage: 12 VDC
Minimum Current Rating: 2 A
Barrel Connector Size: 5.5 mm outer diameter, 2.5 mm inner diameter
Polarity: Positive center
Current Elektron power supply: PSU-2b. These devices were originally shipped with PSU-2. The PSU-2b power supply handles voltages of 100-240 VAC, 50/60Hz.
The power supply you want to use must meet the following specifications:
Voltage: 6 VDC
Minimum Current Rating: 3 A
Barrel Connector Size: 5.5 mm outer diameter, 2.5 mm inner diameter, 6 mm length
Polarity: Positive center
Original (and now obsolete) Elektron power supply: PSU-1 (two versions depending on voltage standard)
Please note that the power supply output must be AC!
The power supply you want to use must meet the following specifications:
Voltage: 6 VAC, 50/60Hz
Minimum Current Rating: 2.5 A
Barrel Connector Size: 5.5 mm outer diameter, 2.5 mm inner diameter, 6 mm length
The power supply you use must meet the following specifications:
Voltage: 6 VDC
Minimum Current Rating: 400 mA
Barrel Connector Size: 5.5 mm outer diameter, 2.1 mm inner diameter
Polarity: Positive center
In most cases, you don't need to use a power supply together with the Overhub. However, if you want to use it together with a non-self powered device (for example, an external hard drive), you must connect a power supply to the Overhub.
Please note that the Overhub is not shipped with a power supply.
The power supply you use must meet the following specifications:
Voltage: 5 V DC
Minimum Current: 4 A (3 A on earlier devices.) This number is written on the Overhub itself so you can see there which version you have.)
Barrel Connector Size: 3.5 mm outer diameter, 1.35 mm inner diameter, 6 mm length
Polarity: Positive center
If you can't find what you are looking for, you may login with your Elektron account and create a support ticket. If you don't have an account already you can create one in the next step.